Also unset the private library if set and make libfprint to only link
with the tod one.
This fixes the issue we had with wrong symbols shared by multiple
libraries
This these functions are not really needed by anything else than
FpDevice, so move them back to the cpp file, so that we don't expose
them in the private library, given that we don't need them
We have an issue where some symbols are exposed by both the tod library
and the public one, and this may lead to big issues like GType's being
defined multiple times.
So add a test checking whether this is working
See: 3v1n0/libfprint#1
It may cause initializing a type twice in some cases, and thus some
hard-locking, let's just avoid it since we don't care about full debug
strings here.
Newer fprintd supports duplicate-detection, this implies sending to the
device an empty prints gallery, expecting the device to give us a
matched print against its storage.
In case the device has no storage we're doing this anyway, but goodix
doesn't handle this properly, so let's just ignore the case if no prints
are passed.
Given that we won't go in the past, it's better to be explicit in
using versions for symbols so that all new symbols will be added to the
latest listed release, while others won't be moved from where they are.
Tag 1.94.2
Git-EVTag-v0-SHA512: 3eed67186b9533300d5ba70ce9abc36055068c3eafa663a48c655ef0e8c7a6928bb7cd875a7ae1860a65324fb806da79d83ca3c97a0640b10dc92dc497f04f11
Expose new versioned symbols that work with previous API so that we can
keep compatibility with old drivers without having to recompile them.
We disable the GCancellable API in delayed SSM actions since that was
something that wasn't really needed and prone to errors, instead of
just re-implementing it as it was in the TOD case.
Recompile tod drivers using libfprint-tod-test-drivers project [1] so
that we don't have to reorder the private driver structure, plus use a
versioned driver ID and parse it to check whether a feature is supported
for such TOD test driver.
https://gitlab.freedesktop.org/3v1n0/libfprint-tod-test-drivers
Tag 1.94.0
Git-EVTag-v0-SHA512: 7cf9d7defb02433140f575589099569a5848ab34e8ecb0a4a90bb3c9eb1c228a16438afe1b23c381b59c1506f189a845752fead3dbd3c1c11f686cf47302cb1b
No need to provide a script that will break usage of `meson test --gdb`
when we can use a native and cleaner alternative.
We can then ignore LIBFPRINT_TEST_WRAPPER in basic tests, while it is
still needed by umockdev tests.
We can avoid having multiple device feature-check functions now and
just rely on a few.
Add uncrustify config to properly handle begin/end deprecation macros.
It can be convenient for device users to check what it supports, without
having multiple functions to check each single feature.
So expose this and add tests.
We always assumed a device can verify, but nothing prevents from having
a device that only can identify or capture.
So, given that we've more fine grained checks, let's stop the task if
this is the case.
Allows drivers to define more fine grained features for devices, not
strictly depending on assumptions we can make depending on the
implemented vfuncs.
We keep this per class but could be in theory moved to each instance.
In any case, added an utility function to initialize it in the way we
can ensure that we've a consistent way for setting them across all the
devices.
We were crashing as trying to still call the identify vfunc, so check if
identification is supported and if not return a relative error.
Added test as well
Tag 1.90.7
Git-EVTag-v0-SHA512: 21642bcdac35b82cd3f56130603d09ebe62b321123f58ce4a491b8fa8f545ae86a7c3d670b212af474d561123efa91f0383ad416b07c3ce1d4df0d292e77bb94
We may want to be able to talk with the device while it's closed to
queue commands to be performed once it opens (could be even a script),
so to do this we need to close the device first, send those commands and
eventually process them.
We used a trick to send an invalid command before that was ignored by
release, but having the device available is just easier to handle.
So, when keep alive is enabled we don't stop the listener when closing
but only on actual device disposition.
The idea of the test was just checking what happens when we're opening a
device multiple times while a first request is still going.
However, it actually ends up also checking the previous commit change
because without it we'd stop the close iteration before the device is
actually closed and stop the open iteration before the device is
actually opened, leading to an infinite loop.
We're delaying any completed operation until we've completed an idle,
but the open/close state is changed and notified as soon as the device
completes the operation.
While this can be true, it means that we notify earlier than the finish
callback is actually called, while iterations are still needed to get
the actual state completed, and the current_task reset.
So if we'd open/close and iterate till fp_device_is_open() returns TRUE
we'd end up in a state in which the device is marked as ready, but it's
actually still busy since it's priv->current_task isn't unset yet.
The same if we'd try to do any action on notify::opened.
In case we do an early error return in verify and identify calls we
do not initialize the task data, but still in the finish functions we
still try to use it.
Avoid doing this, but just nullify the returned values.
When opening the device we can process commands that we left for that
after the previous close, to do that we only have to inject an invalid
command that will be processed (and ignored) while closing, so that at
next device opening we will be able to proceed with the previously
sent commands.
Add tests to finally check this case!